Cable design SLL-240 (Selteq Low Loss 240)
SLL-240 Low Attenuation Coaxial Cable (TZC 500 25) is similar in size to RG-58 cable but has lower attenuation and better shielding. These improvements are achieved by using a foamed dielectric and double shielding.
constructively cable SLL-240 consists of:
– central conductor: solid copper core with a diameter of 1,42 mm
– Internal dielectric made of foamed polyethylene with a diameter of 3,81 mm.
– the first shielding layer made of aluminum foil
– the second shielding layer – braiding of tinned copper with a diameter of 4,52 mm
– Outer protective shell made of polyethylene (PE) with a thickness of 0,8 mm and a diameter of 6,10 mm
Electrical characteristics of the SLL-240 cable
Wave resistance: 50 ohms
Linear capacitance: 79,4 pF/m
Relative speed: 84%
Shortening factor: 1,19
Shielding efficiency: >90 dB
Shell breakdown test voltage: 5000 V (AC)
Peak power: 5,6 kW
Imprint Attenuation: <-18 dB (3-3000 MHz)
Losses and permissible power for SLL-240 cable
Frequency, MHz | Attenuation, dB/100m* | Power, kW* |
150 | 9,9 | 0,66 |
220 | 12,1 | 0,54 |
450 | 17,4 | 0,38 |
900 | 24,9 | 0,26 |
1500 | 32,5 | 0,20 |
1800 | 35,8 | 0,18 |
2000 | 37,7 | 0,17 |
2500 | 42,3 | 0,15 |
5800 | 66,9 | 0,10 |
* Typical values for 20o C and altitude at sea level
Mechanical characteristics of SLL-240 cable
Installation temperature range: -25...+70ºС
Storage temperature range: -55...+85ºС
Operating temperature range: -40...+85ºС
Minimum bending radius: 19,1 mm
Re-bending radius: 63,5 mm
Packaging and labeling
The cable is securely packed on a wooden drum. The standard of packaging is 500 m.
On request, the SLL-240 cable can be cut to shorter lengths.
SLL-240 is similar in size to the following widely used types of HF coaxial cables: LMR 240, MRC 240, WBC-240, WCX 240, SPEEDFOAM 240, TZC 500 25, HUBER+SUHNER S 04272 B.
The SLL-240 cable is slightly thinner than the 5D-FB or RK-50-4-11 cables, but at the same time, the choice of connectors for it is much wider.